Taking Raman Spectroscopy out of the Lab
to the sample!
BaySpec’s Raman Systems are
designed to meet real-world challenges for best-in-class
performance, long-term reliability, compact size and ultra-low
fluorescence interference for Raman instrumentation of biological,
tissue and skin samples. Benefiting from experience manufacturing
high-volume spectral monitoring devices for the telecommunications
industry, BaySpec’s Raman analyzers utilize low-cost field proven
components. For the first time in instrumentation history an
affordable, accurate and ruggedized Raman spectral device is a
reality.
The NunavutTM
Series of Benchtop Raman instruments are
designed for high performance for optical low light spectroscopy.
Designs incorporate BaySpec's high efficiency transmission Volume
Phase Gratings (VPGs), fast f/1.8 optics, and soft (-20°C) or
deep-cooled (-55°C) detector arrays delivering best-in-class
performance. Available in 532m, 785nm and 1064nm excitation
wavelength options. Other options available upon request.
The BaySpec's Handheld and
Portable Raman analyzers are designed for ruggedized, field
deployment and low-cost of ownership. Designed to meet
MILSPEC-810F stringent requirements for humidity, temperature and
ruggedness. Convenient on-board touch-screen PC or cost saving
boothtooth output to an existing smart phone or laptop.
Available in 785nm and 1064nm excitation wavelengths.
Mini-Raman Instrument Catalog
|
Individual Datasheets:
- NunavutTM 785nm Benchtop Raman System
- NunavutTM 1064nm Benchtop Raman System
- Handheld-0 Raman Analyzer (532/785nm)
- Handheld-1 Raman Analyzer (532/785nm)
- Portable-2 Raman Analyzer (1064nm)
- Portability-3TM Raman Instrument
(532/785/1064nm)
|
 |
BaySpec Raman Spectrometer Portfolio
Selection Guide:
|
|

|
|
|
Handheld‐0
|
Handheld‐1
|
Portable‐2
|
Portable‐3
|
Benchtop‐1
|
Benchtop‐x
|
|
Size
|
|
|
|
Dimensions (mm3)
|
93 x 195 x 59
|
125 x 223 x 85
|
140 x 218 x 410
|
240 x 260 x 135
|
134 x 315 x 84
|
Custom
|
|
Weight
|
1 kg (2.2lbs.)
|
2.4kg (4.7lbs.)
|
< 4.6kg (9.9 lbs)
|
< 4.5kg (9.9 lbs)
|
4.6 kg (10 lbs.)
|
Custom
|
|
Excitation Source
|
|
|
|
532nm
|
x
|
x
|
x
|
x
|
x
|
x
|
|
785nm
|
x
|
x
|
x
|
x
|
x
|
x
|
|
1064nm
|
|
|
x
|
x
|
x
|
x
|
|
Custom
|
|
contact BaySpec
|
|
Laser FWHM Bandwidth
|
|
0.2nm typ./ 0.3nm max.
|
|
Output power
|
>80mW
|
0~300mW
|
0~500mW
|
0~500mW
|
0~500mW
|
0~1500mW
|
|
Spectrograph
|
|
|
|
Grating Technology
|
|
Transmission Volume Phase
Grating (VPG ®)
|
|
Range (532nm)
|
300‐3000 cm‐1
|
300‐3000 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
|
|
|
|
300‐2000 cm‐1
|
300‐2000 cm‐1
|
|
|
|
Range (785nm)
|
400‐1800 cm‐1
|
400‐1800 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
|
|
|
|
300‐2000 cm‐1
|
300‐2000 cm‐1
|
|
|
|
Range (1064nm)
|
|
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
300‐3200 cm‐1
|
|
|
|
|
300‐2000 cm‐1
|
300‐2000 cm‐1
|
|
|
|
Spectral Resolution
|
15‐17 cm‐1
|
10‐12 cm‐1
|
4‐5 cm‐1
|
4‐5 cm‐1
|
4‐5 cm‐1
|
4‐5 cm‐1
|
|
Stray Light Reduction
|
0.05%
|
0.05%
|
0.05%
|
0.05%
|
0.05%
|
0.05%
|
|
DetectorDetector
|
|
|
|
Type
|
Uncooled and TE cooled
CCD
|
Uncooled and TE cooled
CCD
|
TE cooled CCD or InGaAs
Array
|
TE cooled CCD or InGaAs
Array
|
TE cooled CCD or InGaAs
Array
|
TE cooled CCD or InGaAs
Array
|
|
Number of pixels
|
1024/2048
|
1024/2048
|
512/1024/2048
|
512/1024/2048
|
512/1024/2048
|
512/1024/2048
|
|
Pixel size
|
14µm
|
14µm or 25µm
|
14µm or 25µm
|
14µm or 25µm
|
14µm or 25µm
|
14µm or 25µm
|
|
Cooling temperature
|
|
‐10°C
|
‐15°C
|
‐15°C
|
‐20°C
|
‐20°C
|
|
(Deep cooling option)
|
|
|
|
|
‐55°C
|
‐55°C
|
|
Integration time
|
20µs ‐300sec.
|
20µs ‐300sec.
|
20µs ‐300sec.
|
20µs ‐300sec.
|
20µs ‐300sec.
|
20µs ‐300sec.
|
|
Readout speed
|
250kHz
|
250kHz
|
250kHz
|
250kHz
|
250kHz
|
250kHz
|
|
Digitalized output
|
16‐bit
|
16‐bit
|
16‐bit
|
16‐bit
|
16‐bit
|
16‐bit
|
|
Dynamic range
|
3000:1 typ.
|
3000:1 typ.
|
3000:1 typ.
|
3000:1 typ.
|
6000:1 typ.
|
6000:1 typ.
|
|
Well Depth
|
200 keˉ
|
200 keˉ
|
130, 200 keˉ
|
130, 200 keˉ
|
130, 200 keˉ
|
130, 200, 700 keˉ
|
|
Quantum Efficiency (max.)
|
>90%
|
>90%
|
>80%
|
>80%
|
>80%
|
>80%
|
|
Electronics
|
|
|
|
Interface
|
|
USB2.0 / RS232 / Ethernet
|
|
Input power
|
+5VDC/+12VDC
|
AC 115‐220V
|
|
Trigger mode
|
|
|
5V TTL edge or level
|
5V TTL edge or level
|
5V TTL edge or level
|
5V TTL edge or level
|
|
Bluetooth
|
x
|
x
|
|
x
|
|
|
|
Battery life
|
4 hrs
|
4 hrs
|
2 hrs
|
2 hrs
|
NA
|
NA
|
|
Software
|
|
|
|
BaySpec "Spec 2020"
|
Micro 2020
, Windows CE
|
Micro 2020
, Windows XP
|
Spec 2020
, Windows XP/Vista, SDK
for development
|
|
Library support
|
|
SDK support for 3rd Party
Libaries available
|
Per informazioni o quotazioni inviate una mail a